Question 1 · HVAC and Engine Cooling System Service, Diagnosis and Repair
An A/C system shows high pressure on both the low and high sides, and cooling is poor at idle. The condenser fan isn't running. What is the likely cause?
- AAn undercharged A/C system
- BA restricted orifice tube
- CPoor condenser airflow
- DA weak, worn compressor
Show answerHide answer
Answer: C. Poor condenser airflow
- ✗ AUndercharge lowers both pressures.
- ✗ BThat lowers the low side.
- ✓ CCorrect. Without the fan, heat isn't removed, so pressures climb.
- ✗ DA weak compressor gives high low-side and low high-side readings.
Question 2 · Refrigeration System Component Diagnosis and Repair
A compressor clutch engages when cold but slips or won't engage when hot. The coil gets proper voltage. What should be checked?
- AThe refrigerant identifier
- BThe clutch air gap
- CThe heater core
- DThe cabin air filter
Show answerHide answer
Answer: B. The clutch air gap
- ✗ AThat doesn't diagnose a clutch.
- ✓ BCorrect. A gap that's too large may not pull in when the coil heats up and weakens.
- ✗ CThat's unrelated.
- ✗ DThat's unrelated.
Question 3 · Operating Systems and Related Controls Diagnosis and Repair
The blower motor works only on the highest speed. What is the most likely cause?
- AA failed blower motor
- BA blown blower motor fuse
- CA failed blower resistor
- DA low refrigerant charge in the system
Show answerHide answer
Answer: C. A failed blower resistor
- ✗ AThe motor works on high, so it's fine.
- ✗ BThen it wouldn't work on any speed.
- ✓ CCorrect. High speed usually bypasses the resistor, so only high still works.
- ✗ DThat doesn't affect blower speed.
What the A7 exam covers
The exam covers 3 areas. The percentages show roughly how much of the exam each one makes up, and our free questions follow the same areas.
HVAC and Engine Cooling System Service, Diagnosis and Repair
Performance testing and pressure diagnosis; Refrigerant service and handling; Heating and engine cooling.
3 topics · 15 free questions
42%Refrigeration System Component Diagnosis and Repair
Compressors and protection devices; Lines, condensers, metering devices and evaporators.
2 topics · 10 free questions
20%Operating Systems and Related Controls Diagnosis and Repair
Electrical controls; Vacuum, mechanical and air distribution; Automatic climate control.
3 topics · 15 free questions
38%
Based on the official A7 exam outline. Check it before you book, since details can change. Break Shift is independent and isn't affiliated with or endorsed by ASE.
Why short shifts work
Short sessions spread over days give better recall than one long sitting, and answering questions teaches more than rereading. So each ASE A7 Heating & A/C shift is one topic, a short guide and five questions, small enough to finish on a break. See the research behind it.
ASE A7 Heating & A/C questions, answered
Are these the real A7 exam questions?
No. Every question is original, written in the exam's style from the official A7 objectives. The questions on the exam itself are confidential, and the exam will word things differently.
Is the ASE A7 Heating & A/C practice free?
Yes. All 40 questions in the free bank, a study guide for every topic and your readiness score are free with an account. No card needed. Premium adds fresh practice written for the topics you miss, and timed concept tests.
How long does a ASE A7 Heating & A/C study shift take?
About fifteen minutes: a short guide to one topic, then five practice questions with the reason behind every answer.